Enerdrive B-TEC LiFeP04 12v 200Ah G2 Lithium Battery
Smart Phone Monitoring System
The Enerdrive Enerdrive B-TEC G2 battery incorporates wireless Battery Monitoring Technology. By downloading the Android™ or Apple® app to your smartphone or tablet device, you can monitor the following information;
- Battery Capacity
- Battery Voltage
- Battery Current (Amps)
- Battery State of Charge (SOC)
- Battery State of Health (SOH)
- Battery Status
- Individual Cell Voltage
- Battery Temperature
- Battery Cycles
- Battery Alarms
- Battery Event Information
Battery Management System
The battery is also equipped with an internal Battery Management System that can monitor and optimise each Prismatic cell within the battery during normal operation. It will protect the battery pack from over charge, over discharge, over temperature & short circuit. The BMS helps to ensure safe and accurate operation of the battery.
Size & Weight Savings
Lithium v AGM Capacities;
- 100Ah Lithium = 160Ah AGM
- 125Ah Lithium = 200Ah AGM
- 200Ah Lithium = 320Ah AGM
(Based on standard depth of discharge for both Lithium (80%) and AGM (50%).
The Enerdrive B-TEC G2 battery provides 60% more usable power than its equivalent lead acid cousin and being nearly 50% lighter and 30% smaller makes for a superior alternative.
The Enerdrive B-TEC G2 battery is perfect for camper trailers, 4WD’s (AUX battery), caravans, small water craft, low power communication sites or any other application that requires the use of a single deep cycle battery that meets the amp hour capacity.
PLEASE NOTE: **DANGEROUS GOODS ONLY, EXTRA DELIVERY CHARGES MAY APPLY. PLEASE CONTACT THE STORE FOR FURTHER INFORMATION**
Cycle Life | ≥ 2000 Cycles |
---|---|
Standard Charge Specification (Lithium profile charger required) | |
Battery Charge Temperature | 0 Ì´ 45°C |
Standby (Float) Voltage | 13.5 Ì´ 13.8V |
Max. Charge Current | 150A @ 25°C for 30mins |
Recommended Charge Current for Maximum Life | ≤60A |
Standard Discharge Specification | |
Battery Discharge Temperature | -20 Ì´ 60°C |
Battery Output Voltage Range | 11.00 Ì´ 14.60V |
Battery Manual Reset Button | Yes |
Discharge Cut-off Voltage | ≤11.20V |
Protection Reset Time | 5s Auto Release |
Short Circuit Protection | Auto release after 5s |
Storage Information | |
Temperature & Humidity Range | ≤ 30 days -20°C Ì´ 35°C, 45 Ì´ 75% RH |
Self-discharge Rate | ≤ 3% Per Month |
Part Number | Nominal Voltage | Nominal Capacity | Weight | L x W x H |
---|---|---|---|---|
ENE-EPL-200BT-12V-G2 | 12.8V | 200Ah | 25kg approx. | 505mm x 173mm x 265mm |
Please Note: The G2 battery is capable to be paralleled to a second G2 battery. For maximum performance and lifespan of your G2 battery, no more than 2 batteries should be connected together to increase your overall capacity. Overall loads when paralleled should not exceed the current limits of a single batteries BMS.
The G2 200Ah battery is able to accept a maximum inverter capacity of 2000W only. Exceeding the maximum inverter capacity can damage the BMS Management within the battery.