Victron Skylla-i Battery Charger - 24V, 3 Outputs
A modern and powerful battery charger.
- The right amount of charge for a lead-acid battery: variable absorption time
- BatterySafe mode: preventing damage due to excessive gassing
- Storage mode: less maintenance and aging when the battery is not in use
- Smaller and lighter compared to similar models
- NMEA 2000 Canbus connection
- PowerControl: set a maximum shore power
- Remote Control
- Li-ion (LiFePo4) readyb
Features:
- Skylla-i (3): three full current outputs to charge 3 battery banks The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current
- Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.
- Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities.
- Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Note: Two output and three output chargers cannot be paralleled with each other.
- The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.
- Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.
- Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.
- Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage.
- Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply.
- Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available.
- Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port.
Part Number | VIC-SKI024080002 | VIC-SKI024100002 |
---|---|---|
Input voltage (V AC) | 230V | 230 V |
Frequency | 45-65 Hz | 45-65 Hz |
Power factor | 0.98 | 0.98 |
Battery capacity | 400-800 Ah | 500-1000 Ah |
Humidity | max 95 % | max 95 % |
Material & Color | Aluminium | Aluminium |
Weight | 7 kg | 7 kg |
H x W x D | 405 x 250 x 150 mm | 450 x 250 x 150 mm |
Part Number | Charge Current | Volts |
---|---|---|
VIC-SKI024080002 | 80 Amp | 24V |
VIC-SKI024100002 | 100 Amp | 24V |