The Meter Interface (MI) accepts inputs from external AC and DC power metering sensors such as: AC and DC voltage and amps, AC kilowatts, and DC battery capacity in amp hours and % remaining.
All with user definable high and low alarms.
AC:
- 3 x AC voltage inputs (multi voltage)
- 2 x AC current inputs
- Calculates true RMS power
DC:
- 3 x DC voltage inputs (multi voltage)
- 2 x DC current inputs
- Calculates battery capacity as ampere hours and percentage charge remaining for two battery banks
- Resolution for current metering down to 0.1A
General:
- Dimensions, WxHxD: 156mm x 100mm x 42mm
- IPX5 water ingress protection
- Outputs standard NMEA2000 power monitoring sentences
Part Number |
---|
BLA-112812 |