Victron BlueSolar MPPT 100/30 & 100/50
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, BlueSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. BlueSolar maintains battery health, extending its life.
- Ultrafast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
- Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
- Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%.
The full output current up to 40°C (104°F).
- Flexible charge algorithm
Fully programmable charge algorithm (see the software page in victronenergy.com), and eight pre-programmed algorithms, selectable with a rotary switch.
- Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
- Internal temperature sensor
Compensates absorption and float charge voltage for temperature.
- Real-time data display options
- ColorControl GX or other GX devices: see the Venus documents on our website.
- A smartphone or other Bluetooth-enabled device: VE.Direct Bluetooth Smart dongle needed.
Check out Victons MPPT Calculator to understand more about your system configuration and yelid.
Part Number | Model | Voltage | Rated Charged Current |
---|---|---|---|
VIC-SCC020030200 | MPPT 100/30 | 100V | 30A |
VIC-SCC020050200 | MPPT 100/50 | 100V | 50A |
BlueSolar Charge Controller | MPPT 100I30 | MPPT 100I50 |
---|---|---|
Battery voltage | 12/24V Auto Select | |
Rated charge current | 30A | 50A |
Nominal PV Power 12V(1a,b) | 440W | 700W |
Nominal PV Power 24V(1a,b) | 880W | 1400W |
Maximum PV open circuit voltage | 100V | 100V |
Max. PV short circuit current(2) | 35A | 60A |
Maximum efficiency | 98% | 98% |
Self-consumption | 12V: 30mA / 24V: 20mA | |
Charge voltage 'absorption’ | Default setting: 14.4V / 28.8V (adjustable) | |
Charge voltage 'float' | Default setting: 13.8V / 27.6V (adjustable) | |
Charge algorithm | Multi-stage adaptive | |
Temperature compensation |
-16mV / °C resp. -32mV / °C |
|
Operating temperature |
-30 to +60°C (full rated output up to 40°C) |
|
Humidity | 95%, non-condesing | |
Data communication port | VE.Direct | |
Enclosure | ||
Colour | Blue (RAL 5012) | |
Power terminals | 16 mm² / AWG6 | |
Protection category | IP43 (electronic components), IP22 (connection area) | |
Weight | 1.3 kg | |
Dimensions (h x w x d) | 130 x 186 x 70mm | |
Standards | ||
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1 V.
2) A PV array with a higher short circuit current may damage the controller.