Victron SmartSolar MPPT 150/35 & 150/45
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
- Bluetooth Smart built-in
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
- VE.Direct
For a wired data connection to a Color Control GX, other GX products, PC or other devices.
- Ultrafast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30 % compared to PWM charge controllers and by up to 10 % compared to slower MPPT controllers.
- Advanced Maximum Power Point Detection in case of partial shading conditions
- If partial shading occurs, two or more maximum power points may be present on the power-voltage curve.
- Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
- The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
- Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98 %. Full output current up to 40 °C (104 °F).
- Flexible charge algorithm
Fully programmable charge algorithm (see the software page on our website), and eight preprogrammed algorithms, selectable with a rotary switch (see manual for details).
- Extensive electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
- Internal temperature sensor
Compensates absorption and float charge voltage for temperature.
- Optional external battery voltage and temperature sensing via Bluetooth
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.
- Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.
Check out Victons MPPT Calculator to understand more about your system configuration and yelid.
Part Number | Model | Voltage | Rated Charged Current |
---|---|---|---|
VIC-SCC115035210 | MPPT 150/35 | 150V | 35A |
VIC-SCC115045212 | MPPT 150/45 | 150V | 45A |
SmartSolar Charge Controller | MPPT 150I35 | MPPT 150I45 |
---|---|---|
Battery voltage | 12/24V Auto Select (software tool needed to select 36V) |
|
Rated charge current | 35A | 45A |
Nominal PV Power (1a,b) | 35A 12V: 500W / 24V: 1000W / 36V: 1500W / 48V: 2000W 45A 12V: 650W / 24V: 1300W / 36V: 1950W / 48V: 2600W |
|
Max. PV short circuit current (2) | 40A | 50A |
Maximum PV open circuit voltage | 150V absolute maximum coldest conditions 145V start-up and operating maximum |
|
Maximum efficiency | 98% | |
Self-consumption | 12V: 20mA / 24V: 15mA / 48V: 10mA | |
Charge voltage 'absorption’ | Default setting: 14.4 / 28.8 / 43.2 / 57.6V (adjustable) | |
Charge voltage 'float' | Default setting: 13.8 / 27.6 / 41.4 / 55.2V (adjustable) | |
Charge algorithm | Multi-stage adaptive (eight pre-programmed algorithms) | |
Temperature compensation |
-16mV / -32 mV / -64mV / °C |
|
Protection | PV reverse polarity Output short circuit Over temperature |
|
Operating temperature |
-30 to +60°C (full rated output up to 40°C) |
|
Humidity | 95%, non-condesing | |
Data communication port | VE.Direct See the data communication white paper on our website |
|
Enclosure | ||
Colour | Blue (RAL 5012) | |
Power terminals | 16 mm² / AWG6 | |
Protection category | IP43 (electronic components), IP22 (connection area) | |
Weight | 1.25 kg | |
Dimensions (h x w x d) | 130 x 186 x 70mm | |
Standards | ||
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 | |
Data Stored | Baterry voltage, current and temperature, as well as load output current, PV voltage and PV current. | |
Number of days trends data is stored | 46 |
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1 V.
2) A PV array with a higher short circuit current may damage the controller.