Victron SmartSolar MPPT 150 VE.Can interface
The MPPT VE.Can SmartSolar charger uses the latest and fastest technology to convert energy from a solar array into energy that optimally charges a battery banks.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
- Ultra Fast Maximum Power Point Tracking
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
- Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points (MPP) may be present on the powervoltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative SmartSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
- Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%. -
Flexible charge algorithm
Fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a rotary switch (see manual for details). -
Extensive electronic protection
Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. PV reverse current protection. -
Bluetooth Smart built-in
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. -
Internal temperature sensor and optional external battery voltage, temperature and current sensing via Bluetooth
A Smart Battery Sense, a BMV-712 Smart Battery Monitor or a SmartShunt can be used to communicate battery voltage and temperature (and current, in case of a BMV-712 or a SmartShunt) to one or more SmartSolar Charge Controllers. -
VE.Direct or VE.Can
For a wired data connection to a Color Control GX, other GX products, PC or other devices. -
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with integrated disconnect function. -
VE.Can: the multiple controller solution
Up to 25 units can be synchronised with VE.Can, and up to 10 units with Bluetooth -
Remote on-off
To connect for example to a VE.BUS BMS. -
Programmable relay
Can be programmed to trip on an alarm, or other events. -
Optional: SmartSolar pluggable LCD display
Simply remove the rubber seal that protects the plug on the front of the controller, and plug-in the display
Check out Victons MPPT Calculator to understand more about your system configuration and yelid.
Part Number | Model | Voltage | Rated Charged Current | Connector |
---|---|---|---|---|
VIC-SCC115070511 | 150/70-MC4 VE.CAN | 150V | 70A | MC4 |
VIC-SCC115085511 | 150/85-MC4 VE.Can | 150V | 85A | MC4 |
VIC-SCC115110511 | 150/100-MC4 VE.Can | 150V | 100A | MC4 |
VIC-SCC115070411 | 150/70-Tr VE.Can | 150V | 70A | Tr |
VIC-SCC115085411 | 150/85-Tr VE.Can | 150V | 85A | Tr |
VIC-SCC115110411 | 150/100-Tr VE.Can | 150V | 100A | Tr |
SmartSolar Charge Controller with VE.Can interface | 150/70 VE.Can | 150/85 VE.Can | 150/100 VE.Can |
---|---|---|---|
Battery voltage | 12/24/48V Auto Select (36 V: manual) | ||
Rated charge current | 70A | 85A | 100A |
Nominal PV power, 12 V(1a,b) | 1000W | 1200W | 1450W |
Nominal PV power, 24 V(1a,b) | 2000W | 2400W | 2900W |
Nominal PV power, 36 V(1a,b) | 3000W | 3600W | 4350W |
Nominal PV power, 48 V(1a,b) | 4000W | 4900W | 5800W |
Max. PV short circuit current(2) | 50A (max 30 A per MC4 conn.) | 70A (max 30 A per MC4 conn.) | |
Maximum PV open circuit voltage | 150V absolute maximum coldest conditions 145V start-up and operating maximum |
||
Maximum efficiency | 98% | ||
Self-consumption | Less than 35mA @ 12V / 20mA @ 48V | ||
Charge voltage 'absorption' | Default setting: 14.4 / 28.8 / 43.2 / 57.6V (adjustable with: rotary switch, display, VE.Direct or Bluetooth) | ||
Charge voltage 'float' | Default setting: 13.8 / 27.6 / 41.4 / 55.2V (adjustable: rotary switch, display, VE.Direct or Bluetooth) | ||
Charge voltage 'equalization' | Default setting: 16.2V / 32.4V / 48.6V / 64.8V (adjustable) | ||
Charge algorithm | Multi-stage adaptive (eight preprogrammed algorithms) or user defined algorithm | ||
Temperature compensation | -16mV / -32mV / -64mV / °C | ||
Protection | PV reverse polarity / Output short circuit / Over temperature | ||
Operating temperature | -30 to +60°C (full rated output up to 40°C) | ||
Humidity | 95%, non-condensing | ||
Maximum altitude | 5000m (full rated output up to 2000m) | ||
Environmental condition | Indoor, unconditioned | ||
Pollution degree | PD3 | ||
Data communication | VE.Can, VE.Direct and Bluetoot | ||
Remote on/off | Yes (2 pole connector) | ||
Programmable relay | DPST AC rating: 240VAC / 4ADC rating: 4 A up to 35VDC, 1 A up to 60VDC | ||
Parallel operation | Yes, parallel synchronised operation with VE.Can (max. 25 units) or Bluetooth (max. 10 units) | ||
Enclosure | |||
Colour | Blue (RAL 5012) | ||
PV terminals(3) | 35mm² / AWG2 (Tr models) Two pairs of MC4 connectors (MC4 models) |
35mm² / AWG2 (Tr models) Three pairs of MC4 connectors (MC4 models) |
|
Battery terminals | 35mm² / AWG2 | ||
Protection category | IP43 (electronic components), IP22 (connection area) | ||
Weight | 3kg | 4.5kg | |
Dimensions (h x w x d) in mm | Tr models: 185 x 250 x 95 mm MC4 models: 215x 250 x 95 mm |
Tr models: 216 x 295 x 103 MC4 models: 246 x 295 x 103 |
|
Standards | |||
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 | ||
Stored Trends | |||
Data stored | Battery voltage,current and temperature, as well as load output current, PV voltage and PV current | ||
Number of days trends data is stored | 46 |
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels Maximum current per MC4 connector: 30A (the MC4 connectors are parallel connected to one MPPT tracker)