Victron SmartSolar MPPT RS 450/100-Tr & 450/200-Tr Bluetooth Solar Charge Controller
The SmartSolar MPPT RS solar charge controllers are Victron's solution for systems with large series connected PV arrays charging 48VDC battery banks. This product is perfect for large off-grid, and grid connected battery systems.
Available in a 5.76kW and 11.52kW model, features include a wide 80-450VDC operating solar voltage input, independent tracking inputs, full connectivity, isolated PV connections, display screen, fully programmable battery charging parameters and active cooling. The new metal case design and fully covered electrical connections improve the safety and modernise the presentation in line with the latest suite of Victron products.
- Ultra-fast Maximum Power Point Tracking (MPPT) Solar Charge Controller
The MPPT RS SmartSolar is a 48V Solar charge controller with up to 450VDC PV input and either 100A, or 200A output. It is used in on-grid and off-grid solar applications where maximum battery charging power is required.
- Multiple independent MPPT tracking inputs
With multiple MPPT trackers, you can optimize your solar panel design for maximum performance for your specific location.
- Isolated PV connections for additional safety
Full galvanic isolation between PV and battery connections provide additional overall system safety.
- Wide MPPT voltage range
80 – 450VDC PV operating range, with a 120VDC PV startup voltage.
- Light weight, efficient and quiet
Thanks to high frequency technology and a new design this powerful charger weighs only 7.9kg for the 100A model. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation.
- Display and Bluetooth
The display reads battery, and controller parameters. The parameters can be accessed with a smartphone or other Bluetooth enabled device. In addition, Bluetooth can be used to set up the system and to change settings with VictronConnect.
- PV Isolation resistance monitoring for peace of mind at higher voltages
The MPPT RS continuously monitors the PV array and can detect if there are faults that reduce the isolation of the panels to unsafe levels.
- VE.Can and VE.Direct port
For connection to a GX device for system monitoring, data logging, and remote firmware updates. VE.Can allows for up to 25 units to be connected together in parallel and synchronize their charging.
- I/O Connections
Programmable Relay, temperature sensor, auxiliary, digital input and voltage sensor connections. The remote input can accept the Victron smallBMS, and other BMS with allow-to-charge signal.
Check out Victons MPPT Calculator to understand more about your system configuration and yelid.
Part Number | Model | Voltage | Rated Charged Current | Connector |
---|---|---|---|---|
VIC-SCC145110510 | Victron SmartSolar MPPT RS 450/100-Tr | 450V | 100A | Tr |
VIC-SCC145120510 | Victron SmartSolar MPPT RS 450/200-Tr | 450V | 200A | Tr |
Isolated SmartSolar MPPT RS | 450I100 | 450I200 |
---|---|---|
Battery voltage | 48V | |
Rated charge current | 100A | 200A |
Maximum charge power | 5.8 kW at 57.6 V | 11.5 kW at 57.6 V |
Charge voltage 'absorption’ | Default setting: 57.6V (adjustable) | |
Charge voltage 'float' | Default setting: 55.2V (adjustable) | |
Programmable voltage range | Minimum: 36V Maximum: 60V(7) |
|
Charge algorithm | Multi-stage adaptive (adjustable) | |
Battery temperature sensor | Included | |
Maximum efficiency | 96% | |
Self-consumption | 15 mA | |
Solar | ||
Maximum DC PV voltage | 450V | |
Start-up voltage | 120V | |
MPPT operating voltage range | 80 – 450V(1) | |
Number of trackers | 2 | 4 |
Max. PV operational input current | 18A per tracker | |
Max. PV short circuit current(2) | 20A per tracker | |
Max. DC output charging power | 4000W per tracker 5760W total |
4000W per tracker 11520W total |
Maximum PV array size per tracker(3) | 7200Wp (450V x 20A)(3) | |
PV Isolation fail level(4) | 100kΩ | |
General | ||
Synchronised Parallel Operation | Yes, up to 25 units with VE.Can | |
Programmable relay(5) | Yes | |
Protection | PV reverse polarity Output short circuit Over temperature |
|
Data communication | VE.Direct port, VE.Can port & Bluetooth(6) | |
Bluetooth frequency | 2402 – 2480MHz | |
Bluetooth power | 4dBm | |
General purpose analogue/digital in port | Yes, 2x | |
Remote on-off | Yes | |
Operating temperature range | -40 to +60°C (fan assisted cooling) | |
Humidity (non-condensing) |
max 95% |
|
Enclosure | ||
Material & Colour | steel, blue RAL 5012 | |
Protection category | IP21 | |
Battery-connection | M8 bolts | |
Power terminals PV input | 2 16mm(2) | |
Weight | 7.9kg | 13.7kg |
Dimensions (h x w x d) in mm | 440 x 313 x 126 | 487 x 434 x 146 |
Standards | ||
Safety | EN-IEC 62109-1, EN-IEC 62109-2 | |
Country of Origin | Designed in The Netherlands, made in India |
1) MPPT operating voltage range is constrained by battery voltage - PV VOC should not exceed 8 x battery float voltage. For example, a 52,8V float voltage results in a maximum PV VOC of 422,4V. See product manual for further information.
2) A higher short circuit current may damage the controller if PV array is connected in reverse polarity.
3) Max. 450VOC result in appr. 360Vmpp, therefor the maximum PV array is appr. 360V x 20A = 7200Wp.
4) The MPPT RS will test for sufficient resistive isolation between PV+ and GND, and PV- and GND. In the event of a resistance below the threshold, the unit will stop charging, display the error, and send the error signal to the GX device (if connected) for audible and email notification.
5) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35VDC and 1 A up to 70VDC
6) The MPPT RS is currently not compatible with VE.Smart Networks.
7) The Charger set-point (float and absorption) can be set to max 60V. The output voltage at the charger terminals can be higher, due to temperature compensation as well as compensation for voltage drop over the battery cables. The maximum output current is reduced on a linear basis from full current at 60V to 5A at 62V. The equalization voltage can be set to max 62V, the equalization current percentage can be set to max 6%.